Nominal voltage | |
---|---|
Specific value | 24 VDC |
Limit values, min/max | 11/27 VDC |
Nominal current, typically | |
Specific value | 20 mA |
Condition | unloaded |
Device design | |
Type | Single-Turn |
Redundant scanning system | yes, double |
Total resolution | <= 12 Bit |
Number of steps per revolution | <= 4096 |
Number of revolutions | 1 |
Accuracy | ± 0,7 ° |
SSI - Interface | |
SSI-Clock input | Optocoupler |
SSI-Data output | RS-485, 2-wire |
SSI-Clock frequency | 80…1000 kHz |
SSI-Mono time, typically | 20 µs |
Parameter/Function, changeable | Resolution |
Output code | |
Number of data bits | |
Adjustment - Parameter | |
SSI-Output | |
Counting direction | |
Type of parametrization | programmable |
Programming - Tool | TR-Soft: TRWinProg |
External inputs | |
F/R | Count direction |
Preset | electronic adjustment |
Logic level | "0“ < +2V, "1“ = Supply |
Concentricity tolerance | 0.2 mm |
Mass, typically | 0.15 kg |
8 (029) 555-8-000 | |
8 (044) 555-8-000 | |
8 (017) 255-8-000 |